← Episodes

insert_bearing

no verdict

arm-01 · 2026-09-24 13:50:40Z · 3.31 s · chain #23

Not accepted. sample interval jitter is 3.04 ms against a 1.04 ms median; clock is not stable enoughKept deliberately: a rig that produces bad data is itself a finding.

Machine verdict

No machine verdict was recorded.

Acceptance criteria

Insert bearing until seated v1

Expected approach → contact → load → release

Observed nothing

peak 5–80 N · slip fails · max 30000 ms

Insert the part until it seats.

Human judgment

Intervention

Human time and robot wait are different costs. Mixing them hides whether to hire another operator or buy another robot.

Contact events (0, offsets from episode start)

No contact events were detected.

Force trace

Downsampled magnitude from the padded window stored in object storage.

Provenance

Cheap to record now, impossible to reconstruct later. Without it an episode cannot be used as training data.

Episode id
e47e264d-2e27-4366-b429-10d73a27f24e
Robot
arm-01
Policy version
pilot-v1
Adapter version
edge-v1
Detector / rules
cd-1 / vr-1
Acceptance criteria version
1
Sensor serial
replay-0000
Sensor calibrated
—
Clock offset (force − frame)
1789100000000.00 ms
Samples recorded
3000
Started / ended
2026-09-24 13:50:40Z → 2026-09-24 13:50:43Z
Sensor archive
Stored

Chain

Position
#23
Integrity
hash matches
Previous
cfbcef746e0ae4b032ffa1a2cf330992
This episode