← Episodes

insert_bearing

no verdict

arm-01 · 2026-09-24 14:00:48Z · 3.32 s · chain #26

Not accepted. sample interval jitter is 3.04 ms against a 1.04 ms median; clock is not stable enoughKept deliberately: a rig that produces bad data is itself a finding.

Machine verdict

No machine verdict was recorded.

Acceptance criteria

Insert bearing until seated v1

Expected approach → contact → load → release

Observed nothing

peak 5–80 N · slip fails · max 30000 ms

Insert the part until it seats.

Human judgment

Intervention

Human time and robot wait are different costs. Mixing them hides whether to hire another operator or buy another robot.

Contact events (0, offsets from episode start)

No contact events were detected.

Force trace

Downsampled magnitude from the padded window stored in object storage.

Provenance

Cheap to record now, impossible to reconstruct later. Without it an episode cannot be used as training data.

Episode id
19bbd39f-bb46-43d9-9c19-8c4071802a00
Robot
arm-01
Policy version
pilot-v1
Adapter version
edge-v1
Detector / rules
cd-1 / vr-1
Acceptance criteria version
1
Sensor serial
replay-0000
Sensor calibrated
—
Clock offset (force − frame)
1789100000000.00 ms
Samples recorded
3000
Started / ended
2026-09-24 14:00:48Z → 2026-09-24 14:00:52Z
Sensor archive
Stored

Chain

Position
#26
Integrity
hash matches
Previous
d04610276e9c9aa339fa5712ec686bf9
This episode